Software features:
Multilanguage user interface*
Test result analysis:
hill of vision deviation,
age norm deviation,
defects progress analysis,
results comparison.
Age-related norms are used, based on 50 000 examinations made in Poland
Possibility of re-testing chosen points
3D presentation window with visualisation of results
Results comparison feature
Possibility to export/import examinations results, enabling moving single test results between computers
Possibility to connect several data bases into one
Possibility to administer data base (moving results of examinations among patients)
Possibility of working in computer net simultaneously by several users
Database sharing with PCT 110 system
Improved module of data base archiving, enabling better,
faster and more effective administration of data base archival copies
Database backup using direct CD-Burning module**
Possibility of saving printouts and examination results as JPG files, and sending in electronic way
Sound events ***
Possibility to data exchange with external medical systems
* in WIN98SE only standard fonts are supported
** computer needs CD/DVD recorder
*** computer needs sound card and speakers
| Number of test points: |
168 + 120 for BY
|
Tested field range:
|
100 deg (130 for drivers test)
|
| Stimulus size: |
Goldmann Size III
|
| Stimulus source: |
LED diode 565 nm, 440 nm for Blue On Yellow
|
| Stimulus intensity: |
from 0,03 asb to 1000 asb (in 3 dB steps)
|
| Standard test fields: |
central 30 deg full 50 deg peripheral 30 deg - 50 deg macula 10 deg glaucoma 22 deg/50 deg driving test nasal 50 deg, temporal 80 deg fast 30 deg user defined 50 deg BDT - Binocular Drivers Test, 80 deg horizontal, 50 deg vertical
|
Power supply:
|
100-250V 50/60Hz
|
Examination strategies: screening, threshold, 3 - zone, fast threshold, neurological, BSV binocular vision, Spatial sensitivity
Flicker (Critical Fusion Frequency measurement), Blue On Yellow (SWAP) strategy (optional), BDT (Binocular Drivers Test)
Eye monitoring by means of built-in CCD-camera
Auto-detection of eye position
Automatic pupil diameter measurement
Automatic adjustment of chin-rest height
Fixation method: control of blind spot position (11 points) digital detection of pupil position
Patient response time: adaptive to patient speed or set manually from 0,1 to 9,9s
Background illumination: 10 asb, set automatically, white color (314 asb yellow color for Blue On Yellow)
Bebie curve
Possibility to print test results in color; alternative printout style (in Humphrey format)
Printer - recommended ink jet or laser jet
Self-diagnostic function checking instruments efficiency
Built-in PC system (PTS-910 Compact only)
Ergonomic design ensures comfortable patient position during examination
Special ventilation system is used to keep fresh air throughout examination inside stimulation bowl (PTS-910/PTS-910 Compact)